New-Build Cavity Wall Ties & Fixings
Precision helical ties for new construction — timber frame, thin joint AAC blockwork, and cavity wall applications up to 4 storeys.
Timber Frame Wall Ties
Thor Helical Timber Frame Ties connect masonry facades to timber frame structures in new buildings up to 4 storeys high. Installed using the Thor Helical Hand Tool by hammering tie into timber frame.
Timber Frame Wall Ties — Performance Data
| ProductCode | Tie Length(mm) | Cavity Width(mm) | Min. Embedment(mm) | Mode | SimulatedShrinkage(mm) | UltimateLoad (N) | DesignLoad (N) |
|---|---|---|---|---|---|---|---|
| M51-0175-A2 | 175 | 50–75 | 65mm masonry / 35mm timber | Tension/Compression | 0 | 770 / 440 | 226 / 146 |
| Tension/Compression | 24 | 870 / 430 | 290 / 143 | ||||
| M51-0200-A2 | 200 | 76–100 | 65mm masonry / 35mm timber | Tension/Compression | 0 | 770 / 440 | 226 / 146 |
| Tension/Compression | 24 | 870 / 430 | 290 / 143 | ||||
| M51-0225-A2 | 225 | 101–125 | 65mm masonry / 35mm timber | Tension/Compression | 0 | 770 / 440 | 226 / 146 |
| Tension/Compression | 24 | 870 / 430 | 290 / 143 | ||||
| M51-0250-A2 | 250 | 126–150 | 65mm masonry / 35mm timber | Tension/Compression | 0 | 770 / 440 | 226 / 146 |
| Tension/Compression | 24 | 870 / 430 | 290 / 143 |
Thin Joint Wall Ties
Thor Helical Thin Joint Wall Ties connect AAC blockwork to a brick facade where thin joints result in misaligned bed joints. Installed using the AT7-SDS-TOOL by driving into blockwork.
Thin Joint Wall Ties — Performance Data
| Product Code | Tie Length (mm) | Cavity (mm) | Mode | Ultimate Load Capacity @ 2.8–3.5 N/mm² (N) | Design Load Capacity @ 2.8–3.5 N/mm² (N) | Ultimate Load Capacity @ 7–10 N/mm² (N) | Design Load Capacity @ 7–10 N/mm² (N) |
|---|---|---|---|---|---|---|---|
| M71-0205-A2 | 205 | 30–50 | Tension / Compression | 1100 / 2030 | 366 / 676 | 1800 / 2030 | 600 / 676 |
| M71-0230-A2 | 230 | 55–75 | Tension / Compression | 1100 / 1860 | 366 / 620 | 1800 / 1860 | 600 / 620 |
| M71-0255-A2 | 255 | 80–100 | Tension / Compression | 1100 / 1770 | 366 / 590 | 1800 / 1770 | 600 / 590 |
| M71-0280-A2 | 280 | 105–125 | Tension / Compression | 1100 / 1370 | 366 / 456 | 1800 / 1370 | 600 / 456 |
| M71-0305-A2 | 305 | 130–150 | Tension / Compression | 1100 / 1100 | 366 / 366 | 1800 / 1100 | 600 / 366 |
Batten Frame Fixings
A cost-effective alternative to plug and screw fixings for securing timber to masonry. A pilot hole through timber and masonry is all that's required — no repositioning of the batten.
Batten Frame Fixings — Test Results
| Diameter (mm) | Substrate | Min. Embedment (mm) | Pilot Hole (mm) | Mode | Model Load Capacity (N) |
|---|---|---|---|---|---|
| 7 | Masonry | 85 | Ø4–5mm | Tension | 1410 |
| 7 | Timber | 25 | Ø4–5mm | Tension | 960 |
Thor Helical Additional Accessories
AT7 SDS Driving Tool
SDS driving tool for installing Ø7mm Thin Joint Wall Ties into AAC blockwork. Fits standard SDS rotary hammers.
Ø5mm Timber Frame Wall Tie
Type 6 conforming tie (BS 5268-6.1:1996) for brick-clad timber frame up to 4 storeys. Installed with AT5-SDS-TOOL — no pilot hole in timber. Accommodates 24mm differential movement.
Thor Helical Hand Tool
Hand tool for installing Timber Frame Wall Ties by hammering the tie into the timber frame structure.
Ø7mm Thin Joint Wall Tie
For AAC blockwork with thin mortar joints. Installed using AT7-SDS-TOOL. Available for 30–150mm cavities. CE & UKCA accredited.
Ø7mm Batten Frame Fixing
Secures timber battens to masonry — no need to reposition batten. Pilot hole through timber and masonry. Cost-effective alternative to plug & screw.